- You have no items in your cart.
- Home /
- StreamMaster II with AVM 2000 GPM (7600 LPM)
Overview
Specifications
Drawings
Installation / Service
Software/Multimedia
Features
See StreamMaster II product pages for StreamMaster II features and functions
Aerial Valve Manifold Features:
- Integrated ball valve to control flow of water to the monitor with MANUAL gear actuator
- Available with Electric or Manual StreamMaster II
- 90° discharge valve with 2 ½” NH threads for extension of hose
- ¼ turn ball valve for smooth operation of discharge valves
- 3 discharge port locations to allow for flexible configurations and options
- StreamMaster II inlet flange on this unit is smaller and lighter weight than standard 4” 150 lb flange, allowing for a compact and light weight total solution. (NOTE: Standard 4” inlet flanged StreamMaster II cannot be used with the AVM – must order as a complete SMII/AVM package).
- Valve extension comes standard with 1” NPT port for customer supplied pressure relief valve if desired)
Available in 5 standard configurations
- S1 - Ladder right valve
- S2 - Ladder left valve
- S3 - Platform right valve
- S4 - Platform left valve
- S5 - Platform dual valve
Applications/Solutions
- Emergency Responder OEMs
- Fire OEMs
- Firefighting - Structural
StreamMaster II with AVM 2000 GPM (7600 LPM) Video
Specifications
Style | 3486 |
---|---|
Warranty | |
Weight | 62.1 lbs (28.2 kg) |
Material | Pyrolite |
Brand | StreamMaster |
Inlet | 4" 150 lb. flange |
Outlet | 3 1/2'' Male (89 mm) |
Flow (GPM) | 2000 |
Flow (LPM) | 7600 |
Volts | 12 V or 24 V |
Style 3486 Electric StreamMaster II with AVM
The 2000 gpm (7600 lpm) rated monitor is to be an all-electric, single waterway monitor constructed of lightweight Pyrolite. The monitor shall have a 3-1/2” (89 mm) NH outlet. The monitor shall have cast-in turning vanes in each elbow. The monitor shall have fully enclosed motors and gears with manual handwheel overrides for both horizontal and vertical rotation and may be operated simultaneously. The monitor is not to exceed 15” (381 mm) high and 11-5/8” (295 mm) wide. The vertical travel shall be from 45° below to 120° above horizontal with adjustable stops at -15°, +45° and +90. The horizontal rotation shall be 355° with physical stops at ±45°, ±90°, ±135° and at ±157°. The monitor shall have absolute position feedback to provide programmable soft stops anywhere within the physical travel range. The control system shall also provide programmable oscillation and obstacle avoidance functions. These programmable features shall be capable of being copied and cloned for fast installment on other monitors using a USB stick. The electronic control system shall be attached to the inlet base of the monitor and be totally encapsulated to prevent moisture intrusion and use locking IP 67 rated electrical connectors for all motor control outputs and control inputs. The control system shall have one environmentally sealed USB port to facilitate control system updates. The control system shall receive commands from J1939 CAN network control devices to control elevation, rotation, nozzle pattern, and electric valve open/close. The control system shall have a built in wireless transceiver to facilitate operation from wireless remote control devices. The aerial valve manifold (AVM) shall be manually operated through a gearbox to open and close the main waterway valve. The base of the AVM shall have a 4” (100 mm), 150 lb flanged inlet. The AVM shall not increase the height of the standard monitor by more than 4.5”. It shall have at least one 90 degree ball valve with 2 ½” NH threads on the outlet. There shall be less than ½ PSI friction loss through the main valve when flowing 2000GPM and it shall be rated for a maximum operation pressure of 250 PSI.
Documents
Name | Sheet # | |
---|---|---|
Style 3486 Order Form |
Access Drawings for Engineers
Contact Us with Questions
Name | Instructions | Last Modified | Type |
---|---|---|---|
Style 3486 STP File - S1 Configuration | 2018-05-16 00:49:38 | ||
Style 3486 STP File - S2 Configuration | 2018-05-16 00:51:26 | ||
Style 3486 STP File - S3 Configuration | 2018-05-16 00:52:33 | ||
Style 3486 STP File - S4 Configuration | 2018-05-16 00:58:21 | ||
Style 3486 STP File - S5 Configuration | 2018-05-16 00:57:01 |
Installation and Service Documents
Contact Us with Questions
Name | Sheet # | |
---|---|---|
Style 3480 & 3482 Parts List - StreamMaster II | 123965 | |
3480 / 3482 StreamMaster II Installation and Operation Instructions | 123966 | |
Style 3486 AVM Parts List | 126810 |
Software Updates and Downloads
Contact Us with Questions
Type | Description | Instructions | Version | Updated | File |
---|
Product Updates and Media Files
Description | Type | Size | |
---|---|---|---|
StreamMaster II Electric Monitor Flyer | n/a | ||
StreamMaster II with Aerial Valve Manifold Video | n/a |
Related Products
1578 |
SaberMaster™ Electric Master Stream Nozzle... |
The SaberMaster nozzles are the only multi-purpose master stream nozzles in the fire service today. Find a distributor n...
|
6039 |
CAN I/O Module... |
The 6039 CAN I/O modules are primarily for use with Akron Brass "on monitor" controls that have limited I/O capability. ...
|
3482 |
StreamMaster II Electric Fire Monitor 1250 GPM (4800 LPM)... |
The Style 3482 StreamMaster™ II mid-range water cannon monitor represents the next level of innovation in fire ... |
3481 |
StreamMaster II Manual Fire Monitor System 2000 GPM (7600 LP... |
The Style 3481 StreamMaster™ II manual water cannon with its multiple patent pending design, provides efficient... |
5178 |
Akromatic 2000 Electric Master Stream Nozzle... |
Akron Brass’ Akromatic 2000 electric master stream nozzle is designed for flows from 500 to 2000 gpm (1900-7600 lpm) a...
|
5177 |
Akromatic 1250 Electric Master Stream Nozzle... |
The Akromatic 1250 electric master stream nozzle is designed for flows from 350 to 1250 gpm (1326-4800 lpm) that have an...
|
4040 |
Akrochem Master Stream Nozzle Electric Pattern Actuation... |
Akrochem nozzles provide both dry chemical application and foam/water application. This flexible nozzle combines the ... |
4042 |
Akrochem 2000 GPM Master Stream Nozzle Electric Pattern Actu... |
Akrochem nozzles provide both dry chemical application and foam/water application. This flexible nozzle combines the ... |
3485 |
3.5" Mini Stream Shaper... |
Designed with built-in offset fins to maximize reach....
|
2498 |
Triple Stacked Tips... |
Stacked Tips
- Chrome plated aluminum - Standard orifices 1-1/2" x 1-3/4" x 2 - Optional orifices 1... |
2499 |
Quad Stacked Deluge Tips... |
These smooth bore nozzle quad stacked deluge tips help you increase tip size quickly and effectively.
|
3499 |
Master Stacked Tips... |
Use stacked tips for a smooth bore nozzle flow. With Pyrolite construction, these master stacked tips will help you f... |
3406 |
Electric Riser for DeckMaster and StreamMaster... |
The electric riser provides an additional 12 inches (305 mm) of extension and is the perfect complement to the already s...
|
6041 |
CAN Toggle Switch Box... |
The 6041 CAN Toggle Switch Box provides monitor positioning control over the J1939 CAN network. This product is part of ...
|
6035 |
CAN Proportional Joystick ... |
The 6035 CAN Proportional Joystick provides precise monitor positioning control over the J1939 CAN network. This prod... |
6036 |
CAN Position Indicator... |
The 6036 CAN Position Indicator provides a graphical representation of monitor position for remote operators that are un...
|
3600 |
Handheld Wireless Remote Control - DISCONTINUED... |
Discontinued effective January 2024 |
6046 |
Diagnostic Interface with Akroview ... |
The 6046 Diagnostic Interface Kit provides a method of connecting a PC to the Akron Brass CAN network This product is pa...
|
6041 |
CAN Tethered Remote... |
The 6041 CAN Tethered Remote provides monitor positioning control over the J1939 CAN network. This product is part of th...
|
6051 |
CAN to CAN Gateway/Repeater... |
The 6051 CAN Gateway/Repeater provides communication between dissimilar network protocols such as J1939 and CANopen. It ...
|