- Home /
- Vehicle Electronics /
- HC-PDM with MFI Inputs
Overview
Specifications
Features
The 4 inputs are polarity selectable inputs and the 4 inputs that have analog capability (0-5volt, 0-30volt, 4-20mA, Thermistor, and Frequency). Input 7 also has the ability to be reconfigured to a voltage reference output that is selectable between 5 volt and 9 volt.
Applications/Solutions
- Emergency Responder OEMs
- Fire OEMs
- Firefighting - Airport (ARFF)
- Firefighting - Industrial
- Firefighting - Structural
- Firefighting - Wildland Forestry
- Rescue - EMS
- Rescue - Hazardous Materials (HazMat)
- Rescue - Urban Search & Rescue
- Rescue - Vehicle Extrication
- Specialty Vehicles
Specifications
Country of Manufacture | US |
---|---|
Weight | 55.7oz (1579.1g) |
Width | 10.313" (261.94mm) |
Height | 6.625" (168.28mm) |
Depth | 2.250" (57.15mm) |
Volts | +9 VDC ... +32 VDC |
Amperage | 73 mA (13.8 VDC) / 82 mA (27.6 VDC) |
Can Specification | SAE J1939 proprietary, 250 Kbits/second |
Enviromental Range | IP 67 |
Electrical protection
- Internal thermal fuse (2500mA on pin 1 of black 12-pin connector)
- CAN bus protected for heavy duty trucks (24V)
- Transient voltage protected to SAE J1113 specification for heavy duty trucks (24V)
- Load dump voltage protected to SAE J1113 specification for heavy duty trucks (24V)
Electrical performance
- Immunity to Radiated Electromagnetic Fields– Bulk Current Injection (BCI) method, Class C device SAE J1113-4
- Reverse voltage protection on power leads (pins 1 and 12 of black 12-pin connector), Class C device ISO 16750-2
- Overvoltage due to failing generator, Class A device ISO 16750-2
- Immunity to conducted transients on power leads, L4 requirements (24V) SAE J1113-11
- Immunity to Electrostatic Discharge – powered and unpowered modes SAE J1113-13
- Immunity to radiated electromagnetic fields, Class C device SAE J1113-21
- Conducted emission on power leads (Class 3 average and Class 5 peak limits) CISPR 25
- Radiated emissions, absorber-lined shielded enclosure (Class 1 average and Class 3 peak limits) CISPR 25
- Reset behavior on voltage drop 24V, Class C device ISO 16750-2
Environmental performance
- Thermal shock SAE J1455 (sec 4.1.3.2)
- Exposure to humidity MIL-STD-810F (method 507.4)
- Thermal shock due to splash Class 1 (STD-0001)
- Pressure cleaning SAE J1455 (sec 4.3)
- Exposure to salt spray atmosphere/fog SAE J1455 (sec 4.3)
- Exposure to splash due to chemicals and oils SAE J1455 (sec 4.4)
- Exposure to outdoor UV ISO 4892-2 (method A)
Mechanical performance
- Resonance dwell SAE J1455 (sec 4.9.4.1)
- Random vibration SAE J1455 (sec 4.9.4.2)
- Mechanical shock SAE J1455 (sec 4.10.3.4)
Installation and Service Documents
Contact Us with Questions
Name | Sheet # | |
---|---|---|
HC-PDM with 4 MFI Inputs | ||
HC-PDM with 4 MFI Inputs One-Page Datasheet |