- Home /
- Vehicle Electronics /
- ITL-40
Overview
Specifications
Installation / Service
Features
The Intelli-Tank Level 40 (ITL40) is designed to display a liquid’s volume to an eighth of a tank level accuracy through 180-degree viewable ultra-bright LEDs. An Intelli-Tank Level 40 set as a MASTER uses a 0-5 PSI (0-34.47 kPa, 0-0.3447 bar) pressure sensor to obtain tank level information and then relays that information along the communication line(s) (1-Wire or CAN) to ITL40’s set as REMOTES. Multiple REMOTE units can be linked to the MASTER tank level.
Applications/Solutions
- Fire OEMs
- Firefighting - Airport (ARFF)
- Firefighting - Industrial
- Firefighting - Structural
- Firefighting - Wildland Forestry
Specifications
Country of Manufacture | US |
---|---|
Weight | 223.96 |
Width | 3.185'' (80.90 mm) |
Height | 5.125'' (120.17 mm) |
Depth | 2.150'' (54.61 mm) |
Volts | +9VDC…+32VDC |
Amperage | 100 mA (13.8 VDC) / 52 mA (27.6 VDC) |
Can Specification | SAE J1939 proprietary, 250 Kbits/second |
Enviromental Range | IP 67 |
1-Wire specification
- Class 1 proprietary, 425 bits/second
Output
- Protected .250 Amp Ground output
Protection
- Internal thermal fuse
- Reverse voltage protection (pins 1 and 12 of connector)
- CAN buses protected to 24V
- ESD voltage protected to SAE J1113 specification for heavy duty trucks
- Transient voltage protected to SAE J1113 specification for heavy duty trucks
Installation and Service Documents
Contact Us with Questions
Name | Sheet # | |
---|---|---|
ITL-40 manual | ||
ITL-40 one-page datasheet |